Hover over image to zoom in

Brand:

generic

100-220V AC Delay Off Time Relay Module Timer Switch Board 0-300min

AED 69.5450% OFF
AED34.77
per pieceIncl. VAT
We accept
COD
Bank transfer
Credit Line

About this item

Power-off delay relay, output when the switch is closed, delay disconnection when the switch is open.

Can set time range 0.2s-300min.

Can set time unit second/minute.

Rotate the adjustable resistor to set the delay time.

With indicator, convenient to detect the status.

Quantity (piece)

Minimum order quantity is 1 piece

Min. Order Quantity:1 piece

Shipping & Returns


Returns
Seller's return policy Learn more

Final price, delivery dates and additional shipping options will be shown at checkout.

Seller information

Verified

China

More from this seller

Overview

Seller SKU ID:
TRE11010190102811D214-14683-24896
Technical specification sheet available by request
No
Dangerous goods
No
Item length
12
Item width
7
Item height
3
Item weight
32
Item weight unit
g
Item dimensions unit
cm

Product description

Item Type: Delay Off Relay Module
Voltage: 100V-220V AC
Power Consumption: Power consumption: Time Range: (4 levels, select by switch)
Level 1: 0.2s-30s, accuracy: 0.1s
Level2: 0.2s-300s, accuracy: 0.3s
Level3: 0.2s-30min, accuracy: 1.8s
Level4: 0.2s-300min, accuracy: 18s
Output: The output voltage is the same as the input voltage, and the power supply capacity is 10A
Life: 100,000 operations
Input: Passive input (switching value trigger, effective over 5ms)
Dimension: 88x36x20mm / 3.46x1.42x0.79in
Screw Holes: Hole Distance: 83x31mm / 3.27x1.22in, Hole Diameter: 3.2mm

Terminal:
L: Live wire input
N: Neutral input input
N1: Neutral wire output, connected to the load
L1: Live wire output, connected to the load
L2: Live wire output (normally closed), generally reserved. (When L1 is off, L2 is on, and when L1 is on, then L2 is off, that is, L1 is opposite to L2)

Instructions:
Time Range Setting:
When the selector switch is set to the 30 position, time range is 0-30
When the selector switch is set to the 300 position, time range is 0-300
Time Value Adjustment:
Turn the adjustable resistor counterclockwise to decrease the time and clockwise to increase the time
Time Unit Setting :
When the selector switch is set to the Sec position, the unit is: second
When the selector switch is set to the Min position, the unit is: minute
Example:
Requires a delay of 50 minutes:
1. Set time range at 300 position
2. Set time unit at Min position
3. Adjust the adjustable resistor to the 50 position

Application:
Use with limit switch and induction switch to achieve:
1. Automatically close the door after timeout
2. Assembly line product interruption monitoring
3. Water/air flow interruption monitoring