Power-off delay disconnection, there is signal - ON, no signal - delay OFF.

Double output contacts.

Each channel maximum current is 5A.

Adjustable time range 0-30/0-300 and time unit second/minute.

Rotate the adjustable resistor to setup delay time.

Quantity (piece)

Minimum order quantity is 1 piece

Min. Order Quantity:1 piece

Shipping & Returns


Returns
Seller's return policy Learn more

Final price, delivery dates and additional shipping options will be shown at checkout.

Seller information

Verified

China

More from this seller

Overview

Seller SKU ID:
TRE11010190099811D214-14683-24622
Technical specification sheet available by request
No
Dangerous goods
No
Item length
11
Item width
7
Item height
3
Item weight
31
Item weight unit
g
Item dimensions unit
cm

Product description

Item Type: Delay Off Relay Module
Voltage: 12V DC (10-16V)
Power Consumption: Output: Passive Output (dry contact), two sets of relay NO + NC output. Do not exceed 5A in each group.
Life: 100,000 actions
Input: Voltage signal, valid signal above 1.5V, current needs at least 0.1mA

Terminal
V+: Power supply +
GND: Power supply -, also the reference GND for the signal voltage
IN: Signal voltage input, low level below 1V, high level above 1.5V, and uncertainty in the middle. Withstands up to 30V
NO1: Relay NO contact 1
NC1: Relay NC contact 1
COM1: Relay contact common terminal 1
NO2: Relay NO contact 2
NC2: Relay NC contact 2
COM2: Relay contact common terminal 2

Time Range Setting:
When the selector switch is set to 30 position, it means that 0-30 is adjustable
When the selector switch is set to the 300 position, it means that 0-300 is adjustable
Time Value Adjustment:
Turn the adjustable resistor counterclockwise to decrease the time and clockwise to increase the time
Time Unit Setting :
When the selector switch is set to the Sec position, the unit is: second
When the selector switch is set to the Min position, the unit is: minute
Example:
Requires a delay of 50 minutes:
1. Set time range at 300 position
2. Set time unit at Min position
3. Adjust the adjustable resistor to the 50 position.

Application:
Use with limit switch and induction switch to achieve:
1. Automatically close the door after timeout
2. Assembly line product interruption monitoring
3. Water/air flow interruption monitoring