There is no exposed metal conductor in the coil, adopt non-contact measurement method, which is safe and reliable.

It is small in size, light in weight, exquisite in appearance, soft and flexible, suitable for narrow environment and flat cable dense place.

It can detect AC leakage current, large current, high-order harmonic current, complex wave current, transient pulse current, phase, power, power factor, etc.

Wide measurement range, high accuracy, strong reliability, the hysteresis effect is not affected by the external electric field, and has a noise free frequency band (0.1 Hz-1 MHz).

The position of the wire is located in the center of the test wire coil, and the influence of position error is less than 0.3% FS.

It is widely used in electric power, communication, meteorology, railway, oil field, architecture, measurement research and teaching units, industrial and mining enterprises and other fields.

كمية (قطعة)

الحد الأدنى لكمية الطلب هو 1 قطعة

الحد الأدنى للطلب:1 قطعة

الشحن والإرجاع


طلبات الإرجاع
سياسة الإرجاع الخاصة بالبائع اعرف المزيد

سيتم عرض السعر النهائي وتواريخ التوصيل وخيارات الشحن الإضافية عند إتمام عملية الشراء والدفع.

معلومات عن البائع

معتمد

الصين

المزيد من هذا البائع

نظرة عامة

معرف وحدة إدارة المخزون للبائع:
TRE11110190043611D214-14683-24262
ورقة المواصفات الفنية متوفرة حسب الطلب
لا
Dangerous goods
No
Item height
2
Item length
21
Item weight unit
g
Item width
15
Item dimensions unit
cm
Item weight
76

وصف المنتج

Condition: 100% Brand New
Item Type: Current Sensor
Material: ABS
Measuring Range: 10A-10000A-Higher
Resolution: 10mA
Precision Grade: ±0.1% FS (50Hz / 60Hz; 23 ℃ ± 2 ℃, Relative Humidity Below 70%, The wire is in the middle of the coil)
Phase Error: ≤0.1° (50Hz / 60Hz; 23℃±2℃)
Output Interface: 3.5mm Audio Plug
Output Line: 2m / 6.6ft
Current Frequency: 45Hz-70Hz (Measured Frequency)
Response Frequency: 0.1Hz - 1MHz
Line Voltage: Below AC1000V Line Test
Working Temperature and Humidity: -20 ℃ - 50 ℃; Relative Humidity Below 80%
Storage Temperature and Humidity: -10 ℃ - 60 ℃; Relative Humidity Below 70%
Dielectric Strength: 2000V / Rms AC (Both ends of the coil)
Coil Length: Approx. 320mm / 12.6in (Adjustable)
Coil Circle Diameter: Approx. 100mm / 3.9in (Adjustable)
Coil Diameter: Approx. 7.5mm / 0.3in (Very suitable for narrow environments and dense cables, etc.)
Function: Detecting of AC leakage current, AC big current, high harmonic current, complex waveforms current, inrush transient current, phase, electric energy, power, power factor.
Testing Method: Flexible CT: The output signal is the derivative of the current with respect to time, the input current can be truly restored by integrating the output voltage signal.